E28/Q28 Safety Exhaust Valve
Brand: Wilkerson CorporationSpecifications
- Easy electrical interface with M12 connectors to safety circuit
- External monitoring provides a cost and space saving advantage
- Solid state pressure sensors provide accurate, fast fault detection
- Quick visual LED indicators on the front of the valve
- Superior seated seal design for longer life
- Safety exhaust outlet is no-maintenance and non-clog by design
- Suitable for stand alone use or modular mounting to FRL assembly
- High B10 life value
Displaying prices & availability for Ohio, United States in USD. Change location.
Featured
- Featured
- Quantity In Stock
- Price
- SKU / Model Number
Models matching criteria: 144
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - No Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - No Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - No Gauge
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - No Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - No Gauge
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - No Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 5 & 2, 1 & 4, Common 3
- Guage - No Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 5 & 4, Common 3
- Guage - Dial Gauge** (Standard)
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 3 & 4
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - Digital Gauge**
Out of Stock
- Series - Safety Redundant with Soft Start
- Thread Type - NPT
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - No Gauge
Out of Stock
- Series - Safety Redundant No Soft Start
- Thread Type - BSPP
- Port Size - 3/4"
- Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
- Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
- Guage - MPS -P34 Gauge
Out of Stock
Specifications
Valve Type
- Externally monitored, Redundant, dual poppet E28: With Soft Start | Q28: No Soft Start
Flow Capacity 1-2
- 145 SCFM or 4,100 L/Min
Exhaust Capacity 2-3
- 265 SCFM or 7,500 L/Min
Ambient Temperature
- 40° to 120° F (4° to 50° C)
Port Threads
- 3/4 inch
Valve Function
- Valve function 3/2 way, normally closed
Weight
- 6.5 lbs (2.9 kg) with Soft Start
- 4.2 lbs (1.9 kg) without Soft Start
Operating Voltage
- 24 VDC
Electrical Connection
- Two M12 connectors
Switching Time 1-2 (ms)
- 23.3
Switching Time 2-3 (ms)
- 42.7
Certifications & Approvals
- Up to Cat 4 PL e (pending)