8189 Guided Microwave Level Measurement Device
Brand: Burkert Fluid Control SystemsThe Type 8189 is a level measurement device with interchangeable rod probe, designed for continuous level measurement. The unit is suitable for liquids, for industrial use in all areas of process technology. But the main application targets are in Food and Beverage (F and B) and pharmaceutical tanks to the new rod in stainless steel 1.4435 with Ra < 0.76 µm.
For applications with corrosive liquids a PFA coated version is available. Even process conditions such as strong steam generation, density fluctuations or changes of the dielectric constant do not influence the accuracy of the measurement. Build-up or condensation on the probe or vessel wall do not influence the measurement result.
Features- Universal level measurement device for liquids
- Liquid interface measurement
- Insensitive to dust and steam
- 4-20 mA/Hart - 2-Wires, ATEX/IECEx approvals
Specifications
Accuracy
- Deviation: ± 2 mm
Ambient Temperature Range
- with Display, Adjustment Elements (Operation & Storage): -40° to 80° C (-40° to 176° F)
Applications
- Foodstuffs & Animal Feed
Approvals & Certifications
- ATEX: EN 60079-0, EN 60079-11, EN 60079-26
- EMC: EN 61326, EN 61010-1
- Ex Ia IIC T6
- FDA
- IECEx TUR 14.0014 X
- NAMUR: NE 21, NE 43
- TÜV
Class
- Protection: Class III (IEC 61010-1)
Communication
- HART
Cover Material
- Polycarbonate (PC)
Current
- 21.5 mA - Maximum
- Fault Signal (Adjustable): ≤ 3.6 mA
- Fault Signal (Adjustable): ≥ 21 mA
Damping Adjustment
- Integration Time (63% of the Input Variable): 0 to 999 seconds
Deadband
- Oil: from Bottom of Probe 100 mm
- Oil: from Top of Probe 150 mm
- Water: from Top of Probe 80 mm (from Bottom of Probe: 0 mm)
Display
- LCD in Full Dot Matrix
Electrical Connectors
- Cable Gland M20 x 1.5
Electrical Rating
- Short Circuit Rating: 131 mA
Enclosure, Body Material
- 316L Stainless Steel, 1.4404
- PBT (Polybutylene Terephthalate)
Environmental Protection
- IP66
- IP67
Humidity
- Operation: 75% Relative Humidity, Maximum
- Storage: 85% Relative Humidity, Maximum
Inductance
- Internal: ≤ 5 µH
Length
- 0.3 to 4 meters - Lateral Load: 10 Nm
Load Resistance
- 1,000 ohms
Materials of Construction
- Ground Terminal: 316L Stainless Steel
Measuring Range
- 0.08 to 4 meters
Operating Voltages
- 9.6-30 Vdc (Ex Ia Instrument)
- 9.6-35 Vdc
- Conformity Specification: 30 V
Output
- 4-20 mA / HART (2-Wire)
Pipe Connection
- DN32 Pipe
- DN40 Pipe
- DN50 Pipe
- DN65 Pipe
Power
- 983 mW
Pressure Range
- bar: -1 to 16
- kPa: -100 to 1,600
- psi: -14.51 to 232.16
Process Temperature
- -20° to 150° C (-4° to 302° F)
Repeatability
- <± 1 mm
Resistance
- 250 ohms
Resolution
- 0.3 µA
Ring Material
- Seal Ring: NBR
Seat / Seal Material
- Process Seal: EPDM
Sensor, Probe Type
- Rod
Thermal Drift
- 0.03% / 10 K
Tri-Clamp Connection
- 1" Sanitary Clamp
- 1-1/2" Sanitary Clamp
- 2" Sanitary Clamp
- 2-1/2" Sanitary Clamp
- 3" Sanitary Clamp
Wetted Materials
- PEEK (Polyetheretherketone)
- Process Fitting (1.4404), Rod-ø 8 mm - Polished: 316L Stainless Steel 1.4435