Adjustment Type
- Factory Set (Pre-Set)
- Field Adjustable
Ambient Temperature Range
- -40° to 71° C (-40° to 160° F)
Approvals & Certifications
Deadband, Approximate
- bar: 2.06 to 25.85
- kPa: 206.84 to 2,585
- psig: 30 to 375
Electrical Connectors
- 1/2" NPT Female, Two 7/8" Diameter Knockouts
- 7/8" Hole to 1/2" NPT Female Watertight Conduit Fitting
Electrical Rating
- 1 A at 125 Vac Resistive
- 10 A at 125 Vac Resistive, Deadband & Minimum Set Point will Increase
- 10 A, 125 Vdc Resistive, Deadband & Minimum Set Point will Increase.
- 15 A 125/250 Vac Resistive
- 15 A 125/250/480 Vac Resistive, 24-30 Vdc, 2 A Resistive & 1 A Inductive, 125 Vdc, 0.5 A Resistive, 0.03 Inductive
- 15 A, 125/250 Vac Resistive, Temperatures up to 121° C (250° F)
- 15 A, 125/250/480 Vac Resistive, Latches on Rise Only
- 20 A, 125/250/480 Vac Resistive
- 30 A, 125/250/277 Vac Resistive
- 5 A at 125/250 Vac Resistive
NPT Connection
- 1/2" NPT Female
- 1/4" NPT Female
Process Connection Material
Proof Pressure
- bar: 689.47
- kPa: 68,947
- psig: 10,000
Set Point - Decreasing
- bar: 5.17 to 344.7
- kPa: 517.1 to 34,4738
- psig: 75 to 5,000
Set Point - Increasing
- bar: 5.17 to 344.7
- kPa: 517.1 to 34,4738
- psig: 75 to 5,000
Standard Features
- Tamper-Resistant Set Point "Lock"
System Pressure
- bar: 413
- bar: 5.17 to 413
- kPa: 41,368
- kPa: 517.1 to 41,368
- psig: 6,000
- psig: 75 to 6,000