Applications
- Biotechnology
- Food & Beverage
- General Chemical Industry
- Pharmaceutical
Approvals & Certifications
- 2-Point Calibration Certificate
- ECR 1935/2004 - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe
- Inspection Certificate 3.1
- Test Report 2.2 - 2-Electrode Conductivity Probe with M12 Connector
- USP Class VI Declaration - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe
Approvals & Certifications
- CE - 2-Electrode Conductivity Probe with M12 Connector
- EHEDG - 4-Electrode Conductivity Probe
- EU Directives - 2-Electrode Conductivity Probe with M12 Connector
- FDA - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe, 2-Electrode Conductivity Probe with M12 Connector
- PED 2014/68/EU - 2-Electrode Conductivity Probe with M12 Connector
BSP Connection
- G 1/4" Male
- G 1-1/4" Male - 4-Electrode Conductivity Probe (Short or Long Insertion Version)
Electrical Connectors
- 5-Pin M12 Male Fixed Connector - 2-Electrode Conductivity Probe with M12 Connector
- Cable, Length 3 meters, Instrument Side with Open Wire - 2-Electrode Conductivity Probe with Cable
- PG13.5 - 4-Electrode Conductivity Probe
- VarioPin (VP 6.0) - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe
Environmental Protection
- IP67 - 2-Electrode Conductivity Probe with M12 Connector
Materials of Construction
- Electrode, Frame: 316L Stainless Steel - 4-Electrode Conductivity Probe (Short or Long Insertion Version) (1.4435), 4-Electrode Conductivity Probe (1.4435), 2-Electrode Conductivity Probe with M12 Connector
- Electrode, Frame: Stainless Steel - 2-Electrode Conductivity Probe with Cable
- Frame: PEEK - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe, 2-Electrode Conductivity Probe with M12 Connector
- Frame: PTFE - 2-Electrode Conductivity Probe with Cable
Measuring Range
- 0.05 to 20 µS/cm - 2-Electrode Conductivity Probe with M12 Connector
- 0.05 to 5,000 µS/cm - 2-Electrode Conductivity Probe with Cable
- 0.1 to 500,000 µS/cm - 4-Electrode Conductivity Probe (Short or Long Insertion Version)
- 1 to 500,000 µS/cm - 4-Electrode Conductivity Probe
Pressure Range
- psi: 0 to 100 (kPa: 0 to 689.5, bar: 0 to 7), Maximum
- psi: 0 to 87.06 (kPa: 0 to 600, bar: 0 to 6), Maximum
Process Temperature
- 120° C (248° F), Maximum
- -20° to 135° C (-4° to 275° F) - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe
- -20° to 150° C (-4° to 302° F) - 2-Electrode Conductivity Probe with M12 Connector
Response Time
- t90: 60 seconds - 2-Electrode Conductivity Probe with M12 Connector
Sensor, Probe Type
- Probe: 2-Electrode - 2-Electrode Conductivity Probe with M12 Connector, 2-Electrode Conductivity Probe with Cable
- Probe: 4-Electrode - 4-Electrode Conductivity Probe (Short or Long Insertion Version) & 4-Electrode Conductivity Probe
Tri-Clamp Connection
- 1-1/2" Tri-Clamp® - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 2-Electrode Conductivity Probe with M12 Connector, 2-Electrode Conductivity Probe with Cable
- 2" Tri-Clamp® - 4-Electrode Conductivity Probe