Ambient Temperature Range
- 55° C (131° F), Maximum
- Block Mounting: -30° to 50° C (-22° to 122° F) - ATEX/IECEx Version
- Single Mounting: -30° to 60° C (-22° to 140° F) - ATEX/IECEx Version
Approvals & Certifications
- ATEX - PTB 14 2023 x (with Moulded Cable: II 2 G Ex Mb IIC T5 Gb, II 2D Ex Mb IIIC T 100° C Db), EPS 16 1046 x (with Junction Box: II 2 G EX Eb Mb IIC T5 Gb, II 2D EX Mb Tb IIIC T100° C Db)
- CE
- IEC Ex - PTB 14.0049 x (with Moulded Cable: II 2 G Ex Mb IIC T5 Gb, II 2D Ex Mb IIIC T 100° C Db), EPS 16.0021 x (with Junction Box: II 2 G EX Eb Mb IIC T5 Gb, II 2D EX Mb Tb IIIC T100° C Db)
- ISO 8573-1:2010, Class 7.4.4
Consumption
- Power Consumption (Version with Vac Voltage): 11 VA (Inrush)
- Power Consumption (Version with Vac Voltage): 6 VA (Hold)
- Power Consumption (Version with Vdc Voltage): 2 W
Electrical Connectors
- 3 meters Cable, Moulded - ATEX/IECEx Version
- Junction Box (without Fuse), Moulded - ATEX/IECEx Version
- M20 x 1.5 - ATEX/IECEx Version with Junction Box
- Tag Connectors According to DIN 43650 (Previously DIN 43650) Form A for Cable Plug Typical 2508
Enclosure, Body Material
- Polyamide (Reinforced) with Moulded-in Brass Threads
Flow Rate
- QNn-Value Air: 900 L/minute
Materials of Construction
- Coil: Epoxy
- Coil: Polyamide
- Moulded-in Thread: Brass
- Poppet: Plastic
- Silencer: Sintered Bronze
- Stopper, Magnet Core: 430FR Stainless Steel
Media
- Lubricated Compressed Air
- Neutral Medium
- Non-Lubricated Compressed Air
Mounting Position
- Preferably with Solenoid System Upright
Operating Voltages
- 24 Vdc
- 24-230 V at 50/60 Hz
- 24-230 VUC - ATEX/IECEx Version
Pressure Range
- psi: 14.5 to 145 (kPa: 100 to 1,000, bar: 1 to 10)
Process Temperature
- -10° to 60° C (14° to 140° F)
Response Time
- Closing: 30 milliseconds (Pressure Drop 100 to 10%)
- Opening: 50 milliseconds (Pressure Rise 0 to 90%)