Ambient Temperature Range
- -10° to 55° C ( 14° to 131° F)
Duty Cycle
- Continuous Operation (100%)
Electrical Connectors
- Pneumatic Module: G 1/8"
- Pneumatic Module: Push-In Connection Ø 0.3" (8 mm)
- Tag Connector According to DIN EN 175301-803 (Previously DIN 43650) Form C-Typical 2506
Flow Rate
- QNn Value Air: 700 L/minute
Media
- Lubricated Dry Air
- Neutral Gases (10 μm Filter)
- Non-Lubricated Dry Air
Mounting Position
- Preferably Solenoid System Upright
Pressure Range
- psi: 14.5 to 145 (kPa: 100 to 1,000, bar: 1 to 10)
Process Temperature
- -10° to 50° C (14° to 122° F)
Response Time
- Closing: 12 to 17 milliseconds (Measures According to ISO 12238)
- Opening: 20 milliseconds (Measures According to ISO 12238)