8010 Inline Paddle Wheel Flow Switch

Brand: Burkert Fluid Control Systems

The Inline flow sensor/switch Type 8010 is specially designed for use in pure and water resembling fluids, free from air bubbles and magnetizable particles, to monitor minimum/maximum values of flow. The sensor/switch is made up of a sensor fitting (Type S010) and an electronic module (Type SE10), quickly and easily connected together by a Quarter-Turn. 

The 8010, which is uni-directional, should be mounted in respect of the arrow that indicates the flow direction. The device indicates the presence of a flow in the pipe by switching the Reed contact contained in the electronic module. The switching points minimum/maximum for rising and falling velocities can be set with a screw within a defined range.
Features
  • Economic integration in pipe systems without any additional piping
  • Magnetic measuring principle
  • Mechanical adjustment of setpoint

Specifications

Ambient Temperature Range

  • Operating & Storage: 0° to 55° C (32° to 131° F)

Approvals & Certifications

  • CE
  • EU Directives
  • PED 2014/68/EU

BSP Connection

  • G 1" Female
  • G 1" Male
  • G 1/2" Female
  • G 1-1/2" Female
  • G 1-1/2" Male
  • G 1-1/4" Female
  • G 1-1/4" Male
  • G 2" Female
  • G 3/4" Female
  • G 3/4" Male
  • 1" BSPT Female
  • 1/2" BSPT Female
  • 1-1/2" BSPT Female
  • 1-1/4" BSPT Female
  • 2" BSPT Female
  • 3/4" BSPT Female

Cable Length

  • 328.1 feet (100 meters), Maximum

Cover Material

  • 20% Glass Fibre Reinforced

Diameter

  • Pipe: 1/2 to 2" (DN15 to DN50)

Electrical Connectors

  • 0.14 to 0.5 mm² Cross Section
  • Cable Plug: EN 175301-803

Electrical Contacts

  • Normally Closed
  • Normally Open
  • Reed Contact

Electrical Rating

  • 0.8 A at 150 Vdc / 250 Vac, Maximum
  • 2.5 A at 50 W, Maximum

Enclosure, Body Material

  • Polycarbonate (PC)

Environmental Protection

  • IP65

Flange Size - 1-1/2" (DN40)

  • 1-1/2" (DN40) - JIS 10K (ANSI B16-5)
  • 1-1/2" (DN40) - PN 16 (EN1092-1/B1)

Flange Size - 1-1/4" (DN32)

  • 1-1/" (DN32) - JIS 10K (ANSI B16-5)
  • 1-1/4" (DN32) - PN 16 (EN1092-1/B1)

Flange Size - 1" (DN25)

  • 1" (DN25) - JIS 10K (ANSI B16-5)
  • 1" (DN25) - PN 16 (EN1092-1/B1)

Flange Size - 1/2" (DN15)

  • 1/2" (DN15) - JIS 10K (ANSI B16-5)
  • 1/2" (DN15) - PN 16 (EN1092-1/B1)

Flange Size - 2" (DN50)

  • 2" (DN50) - JIS 10K (ANSI B16-5)
  • 2" (DN50) - PN 16 (EN1092-1/B1)

Flange Size - 3/4" (DN20)

  • 3/4" (DN20) - JIS 10K (ANSI B16-5)
  • 3/4" (DN20) - PN 16 (EN1092-1/B1)

Flow Rate

  • 10 m/sec, Maximum

Humidity

  • ≤ 80% Relative Humidity, Non-Condensing

NPT Connection

  • 1" NPT Female
  • 1/2" NPT Female
  • 1-1/2" NPT Female
  • 1-1/4" NPT Female
  • 2" NPT Female
  • 3/4" NPT Female

O-Ring Material

  • EPDM
  • FKM

Pipe Connection

  • DN15 Pipe
  • DN20 Pipe
  • DN25 Pipe
  • DN32 Pipe
  • DN40 Pipe
  • DN50 Pipe

Plug Material

  • Cable Plug: Polyamide (PA)

Pressure Range

  • with Metal Sensor Fitting - psi: 0 to 232.1 (kPa: 0 to 1,600, bar: 0 to 16), Maximum
  • with Plastic Sensor Fitting - psi: 0 to 145 (kPa: 0 to 1,000, bar: 0 to 10), Maximum

Process Connection Material

  • Metal
  • Plastic

Process Temperature

  • with Sensor Fitting in PP, PVDF, Brass, Stainless Steel: 0° to 55° C (32° to 131° F)
  • with Sensor Fitting in PVC: 0° to 50° C (32° to 122° F)

Screw Material

  • Setting Screw: Plated Brass

Seat / Seal Material

  • Seal: EPDM
  • Seal: FKM

Switch Point Range

  • 4.7 to 75.4 L/minute

Tri-Clamp Connection

  • DN15 Tri-Clamp®
  • DN20 Tri-Clamp®
  • DN25 Tri-Clamp®
  • DN32 Tri-Clamp®
  • DN40 Tri-Clamp®
  • DN50 Tri-Clamp®

Viscosity

  • 100 cSt, Maximum

Welded Connection

  • DN 15 Weld End
  • DN 20 Weld End
  • DN 25 Weld End
  • DN 32 Weld End
  • DN 40 Weld End
  • DN 50 Weld End

Wetted Materials

  • Fitting, Sensor Holder & Axis: 316L Stainless Steel, 1.4404
  • Fitting, Sensor Holder & Blade: PVDF
  • Fitting, Sensor Holder: Brass (CuZn₃₉Pb₂)
  • Fitting, Sensor Holder: Polypropylene (PP)
  • Fitting, Sensor Holder: PVC

show more