8056 Full Bore Magmeter, Hygienic Connection
Brand: Burkert Fluid Control SystemsThe complete full bore magflowmeter Type 8056, which consists of a magnetic sensor fitting Type S056 connected to an electronics Type SE56 (blind in compact version or with display in compact or remote version) is designed for applications with liquids with a minimum conductivity of 5 µS/cm. Combined with a valve as the actuating element, the complete magflowmeter Type 8056 can control high-precision dosing operations and flow measurement in food and beverage or pharmaceutical industry.
Features- Combination of magflowsensor fitting S056 and electronics SE56
- Continuous measurement or Batch Control
- Sanitary version, certificate
- Dedicated to food and beverage or pharmaceutical applications
- Low-flow measurements on from 3 l/h
Specifications
Applications
- Food & Beverage
- Pharmaceutical Applications
Approvals & Certifications
- CE
Approvals & Certifications
- 3A Sanitary
Cable Length
- Electrode & Coil Cable: 10 meters
Conductivity
- 20 µS/cm Minimum with Demineralized Water
- 5 µS/cm Minimum
Electrical Connectors
- 2 Cable Glands PG9
Enclosure, Body Material
- 304 Stainless Steel
Environmental Protection
- IP65
- IP67
- IP68
Flow Rate
- Maximum
- Minimum 0 to 0.04 m/sec: 0 to 11.20 m³/hour
- Minimum 0 to 0.04 m/sec: 0 to 500 L/hour
Materials of Construction
- Electrode: 316L Stainless Steel
- Lining: PTFE
- Pipe: Stainless Steel
Measuring Range
- 0 to 10 L/hour
- 0 to 280 m³/hour
Pipe Connection
- DN10 Pipe
- DN100 Pipe
- DN15 Pipe
- DN20 Pipe
- DN25 Pipe
- DN3 Pipe
- DN32 Pipe
- DN40 Pipe
- DN50 Pipe
- DN6 Pipe
- DN65 Pipe
- DN80 Pipe
Pressure Range
- bar: 0 to 16
- kPa: 0 to 1,600
- psi: 0 to 232
Process Temperature
- -20° to 130° C (-4° to 266° F)
Seat / Seal Material
- Seal: EPDM
- Seal: FKM
Tri-Clamp Connection
- DN10 Sanitary Clamp
- DN100 Sanitary Clamp
- DN15 Sanitary Clamp
- DN20 Sanitary Clamp
- DN25 Sanitary Clamp
- DN3 Sanitary Clamp
- DN32 Sanitary Clamp
- DN40 Sanitary Clamp
- DN50 Sanitary Clamp
- DN6 Sanitary Clamp
- DN65 Sanitary Clamp
- DN80 Sanitary Clamp
Vacuum Pressure
- Vacuum Resistance - psi: 2.9 (kPa: 20, Mbar: 200) Absolute at 100° C (212° F)