J21K Series Type J21K Models 232 & 254 Differential Pressure Switch

Brand: United Electric Controls Ltd.

The J21K differential pressure switch monitors the difference between two system pressures or vacuums and senses excessive flow deviation, or verifies that a filter is clogged. The J21K's rugged design - with epoxy coated enclosure and sealed metal bellows - lends itself to exacting applications. Widely used in refrigeration (chiller) and compressor applications, the J21K can be used for filter status monitoring and proof of flow.
Features
  • Sealed metal bellows sensors
  • Welded 316 stainless steel sensors
  • Gasketed die-cast aluminum enclosure with epoxy coating
  • Single switch output
  • Adjustable ranges: 30" Hg vac to 90 psid (-1 to 6 bar)
  • Designed to meet enclosure Type 4X (with watertight conduit fitting)
  • UL listed and cUL certified
  • Optional ATEX and Rostechnadzor
  • (GOST-R) intrinsic safety compliance
  • Optional adjustable deadband
  • Single switch output
  • Opposing bellows design

Specifications

Ambient Temperature Range

  • -40° to 71° C (-40° to 160° F), Set Point Typically Shifts less than 1% of Range for a 28° C (50° F) Ambient Temperature Change

Applications

  • Refrigeration (Chiller) & Compressor

Approvals & Certifications

  • ISO 9001

Approvals & Certifications

  • ATEX Ex Directive (94/9/EC) II 1 G EEx Ia IIC T6, Tamb: -50° to 60° C (-58° to 140° F)
  • CE
  • GOST R 51330.0, 51330.1, 51330.10 & 51330.14
  • Low Voltage Directive (LVD) 73/23/EC & 93/68/EEC
  • PED: 97/23/EC
  • UL (C,US)

Deadband

  • psi: 0.6 to 4 (kPa: 4.14 to 27.58, Mbar: 41.37 to 275.8)

Electrical Connectors

  • 7/8" Diameter Conduit Hole

Electrical Contacts

  • Gold
  • Normally Closed
  • Normally Open

Electrical Rating

  • 1 A at 125 Vac Resistive
  • 15 A at 125/250/277 Vac Resistive
  • 5 A at 125/250 Vac Resistive

Enclosure Finish

  • Epoxy Powder-Coated

Enclosure, Body Material

  • Gasketed Die Cast Aluminum

Environmental Protection

  • IP66
  • NEMA 4X

NPT Connection

  • 1/4" NPT Female

Operating Pressure

  • psi: -14.7 to 200 (kPa: -101.4 to 1,379, bar: -1 to 13.8)

Process Connection Material

  • Phosphor Bronze Bellows

Proof Pressure

  • Differential Proof Pressure - psi: 25 to 90 (kPa: 172.4 to 620.5, bar: 1.7 to 6.2)

Repeatability

  • ± 1% of Full Scale Range

Set Point - Decreasing

  • bar: 0 to 6.2
  • kPa: 0 to 620.5
  • psid: 0 to 90

Set Point - Increasing

  • bar: 0 to 6.2
  • kPa: 0 to 620.5
  • psid: 0 to 90

Shock

  • Set Point Repeats after 15 G, 10 millisecond Duration

Storage Temperature

  • -54° to 71° C ( -65° to 160° F)

Switch Type

  • One SPDT Snap-Action Switch

System Pressure

  • bar: 13.79
  • kPa: 1,379
  • psi: 200

Vibration

  • Set Point Repeats after 2.5 G, 5 to 500 Hz
show more