Price
Request a Quote
Stock
Out of Stock

  • Series - Safety Redundant No Soft Start
  • Thread Type - BSPP
  • Port Size - 3/4"
  • Output for Solenoid, M12 Connector Pin - 2 & 4, Common 3
  • Output for Sensors, M12 Connector Pin - 1 & 2, 1 & 4, Common 3
  • Guage - MPS -P34 Gauge

Specifications

Valve Type

  • Externally monitored, Redundant, dual poppet E28: With Soft Start | Q28: No Soft Start

Flow Capacity 1-2

  • 145 SCFM or 4,100 L/Min

Exhaust Capacity 2-3

  • 265 SCFM or 7,500 L/Min

Ambient Temperature

  • 40° to 120° F (4° to 50° C)

Port Threads

  • 3/4 inch

Valve Function

  • Valve function 3/2 way, normally closed

Weight

  • 6.5 lbs (2.9 kg) with Soft Start
  • 4.2 lbs (1.9 kg) without Soft Start

Operating Voltage

  • 24 VDC

Electrical Connection

  • Two M12 connectors

Switching Time 1-2 (ms)

  • 23.3

Switching Time 2-3 (ms)

  • 42.7

Certifications & Approvals

  • Up to Cat 4 PL e (pending)
show more