CamCor CT Coriolis Flow Meter & Transmitter

Brand: Cameron

Equipped with a sophisticated transmitter (including extensive diagnostics, a large display, and field configurability via keypad), the Cameron CT Series are high-performance Coriolis flow meters capable of mass flow measurement with a high degree of accuracy. Particularly worth noting are its uses in non-routine flow rate measurement, including measurement of extra low-volume flows, short-duration filling processes, etc.
Features
    Outstanding zero stability performance High-accuracy density: ±0.0005 g/mL (Models CC003 to CC250) Fast response and calculation frequency Dual independent pulse outputs, dual independent Analog outputs, one status input and one status output Configurable via keypad or digital communications Extensive self-diagnostic capabilities (connection faults, pipeline vibration, media pulsation, etc.) Enhanced maintenance functions (event/user change logging and downloads, recoverable factory configuration and calibration, etc.) User-configurable alarms Compatible with HART and Modbus communication protocols

    Specifications

    Brand

    Accuracy

    • High-Accuracy Density: ± 0.0005 G/mL

    Ambient Temperature Range

    • -40° to 55° C (-40° to 131° F)

    Approvals & Certifications

    • ATEX: 94/9/EC, EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-11: 2012
    • CSA: Class I, Zone 1, Ex D Ib IIB T4 Gb, Class I, Zone 1, Ex D [ib] IIB T6 Gb
    • EMC Directive: 2004/108/EC, EN 55011: 1998, A1, 1999, A2: 2002, Group 1, Class B, EN 61000-6-2: 2001, EN061326-1:2006
    • IEC Ex: IEC60079-0: 2011, IEC60079-1: 2007-04, IEC60079-11: 2011

    Communication

    • HART
    • Modbus

    Conduit Connection

    • 3/4" NPT Female

    Configuration

    • Integral - Transmitter
    • Separately Mounted - Transmitter

    Consumption

    • Maximum

    Damping Adjustment

    • Density: 4 seconds
    • Flow Rate: 0.8 second
    • Temperature: 2.5 seconds

    Density Range

    • 0.3 to 2 G/mL - Metering Range (Liquid)

    Display

    • 128 x 64 Dots LCD
    • Backlit
    • LCD & LED

    Electrical Connectors

    • Minimum Conductor Size: 18 AWG

    Enclosure Finish

    • Paint Color: Light Gray (RAL7035)
    • Paint Typical: Baked Enamel

    Enclosure, Body Material

    • 304 Stainless Steel

    Environmental Protection

    • IP66
    • IP67

    Flange Size - 1-1/2" (DN40)

    • 1-1/2" (DN40) - 150# (ASME)
    • 1-1/2" (DN40) - 300# (ASME)
    • 1-1/2" (DN40) - 600# (ASME)
    • 1-1/2" (DN40) - 900# (ASME)
    • 1-1/2" (DN40) - PN 10
    • 1-1/2" (DN40) - PN 16
    • 1-1/2" (DN40) - PN 25
    • 1-1/2" (DN40) - PN 40

    Flange Size - 1" (DN25)

    • 1" (DN25) - 150# (ASME)
    • 1" (DN25) - 300# (ASME)
    • 1" (DN25) - 600# (ASME)
    • 1" (DN25) - 900# (ASME)
    • 1" (DN25) - PN 10
    • 1" (DN25) - PN 16
    • 1" (DN25) - PN 25
    • 1" (DN25) - PN 40

    Flange Size - 1/2" (DN15)

    • 1/2" (DN15) - 150# (ASME)
    • 1/2" (DN15) - 300# (ASME)
    • 1/2" (DN15) - 600# (ASME)
    • 1/2" (DN15) - 900# (ASME)
    • 1/2" (DN15) - PN 16
    • 1/2" (DN15) - PN 25
    • 1/2" (DN15) - PN 40
    • 1/2" (DN15) - PN10

    Flange Size - 10" (DN250)

    • 10" (DN250) - 150# (ASME)
    • 10" (DN250) - 300# (ASME)
    • 10" (DN250) - 600# (ASME)
    • 10" (DN250) - PN 10
    • 10" (DN250) - PN 16
    • 10" (DN250) - PN 25
    • 10" (DN250) - PN 40

    Flange Size - 2" (DN50)

    • 2" (DN50) - 150# (ASME)
    • 2" (DN50) - 300# (ASME)
    • 2" (DN50) - 600# (ASME)
    • 2" (DN50) - 900# (ASME)
    • 2" (DN50) - PN 10
    • 2" (DN50) - PN 16
    • 2" (DN50) - PN 25
    • 2" (DN50) - PN 40

    Flange Size - 3" (DN80)

    • 3" (DN80) - 150# (ASME)
    • 3" (DN80) - 300# (ASME)
    • 3" (DN80) - 600# (ASME)
    • 3" (DN80) - 900# (ASME)
    • 3" (DN80) - PN 10
    • 3" (DN80) - PN 16
    • 3" (DN80) - PN 25
    • 3" (DN80) - PN 40

    Flange Size - 4" (DN100)

    • 4" (DN100) - 300# (ASME)
    • 4" (DN100) - 600# (ASME)
    • 4" (DN100) - PN 10
    • 4" (DN100) - PN 16
    • 4" (DN100) - PN 25
    • 4" (DN100) - PN 40
    • 4" (DN100) 150# (ASME)

    Flange Size - 6" (DN150)

    • 6" (DN150) - 150# (ASME)
    • 6" (DN150) - 300# (ASME)
    • 6" (DN150) - 600# (ASME)
    • 6" (DN150) - PN 10
    • 6" (DN150) - PN 16
    • 6" (DN150) - PN 25
    • 6" (DN150) - PN 40

    Flange Size - 8" (DN200)

    • 8" (DN200) - 150# (ASME)
    • 8" (DN200) - 300# (ASME)
    • 8" (DN200) - 600# (ASME)
    • 8" (DN200) - PN 10
    • 8" (DN200) - PN 16
    • 8" (DN200) - PN 25
    • 8" (DN200) - PN 40

    Flange Type

    • Raised Face (RF)

    Flow Rate

    • 0.00088 to 514 Lbs/min - Guaranteed Minimum Mass Flow Rate
    • 0.0044 to 2572 Lbs/min - Minimum Setting of Mass Flow Rate
    • 0.088 to 51441 Lbs/min - Maximum
    • 0.132 to 102883 Lbs/min - Maximum

    Media

    • Gas
    • Liquids

    Mounting Position

    • Horizontal Piping
    • Vertical Piping

    NPT Connection

    • 1/2" NPT Female
    • 1/4" NPT Female
    • 3/4" NPT Female

    O-Ring Material

    • Fluoroelastomer
    • PTFE
    • Viton

    Operating Pressure

    • psi: 142 (kPa: 979, bar: 9.79), Maximum
    • psi: 2,176 (kPa: 15,000, bar: 150), Maximum

    Output

    • 10-30 V, 50 mA DC - Open Collector Pulse Output
    • 4-20 mA DC, Maximum

    Output Format

    • Pulse Output

    Output Impedence

    • 2.2 KiloOhms - Pulse Output

    Power Supply

    • 20-30 Vdc
    • 85-264 Vac, 50/60 Hz

    Pressure Range

    • psig: 203 to 1,044 (kPa: 1,400 to 7,198, bar: 14 to 71.98) - Sensor Housing Withstand

    Range

    • Transmission Length of Separately-Mounted: 656 feet (200 meters)
    • Transmission Length: up to 3937 feet (1,200 meters) at 100 Hz

    Repeatability

    • ± 0.05% of Reading (± 1/2 ZS) at Liquids
    • ± 0.1% of Reading (± 1/2 ZS) at Liquids
    • ± 0.25% of Reading (± 1/2 ZS) at Gases

    Resistance

    • Pulse Ouput ON Resistance: ≤ 0.6 ohm
    • Status Output ON Resistance: ≥ 0.6 ohm

    Response Time

    • 25 to 50 milliseconds

    Rotation

    • Bi-Directional - Flow Direction

    Stability

    • 0.000013 to 2.572 Lbs/min - Zero Stability

    Temperature Range

    • -200° to 200° C (-328° to 392° F)

    Tri-Clamp Connection

    • 1" IDF Ferrule
    • 1/2" IDF Ferrule
    • 1-1/2" IDF Ferrule
    • 2" IDF Ferrule
    • 3" IDF Ferrule

    Uncertainty

    • ± 0.003 G/mL - Uncertainty of Density (Liquid)
    • ± 0.1% of Full Scale - Analog Output Uncertainty
    • ± 0.2% of Reading (± Zero Stability) - Uncertainty of Flow Rate (Liquid)
    • ± 0.5% of Reading (± Zero Stability) - Uncertainty of Flow Rate (Gas)

    Wetted Materials

    • 316L Stainless Steel
    • Alloy C22 (Hastelloy®)
    show more