Ambient Temperature Range
- -10° to 55° C ( 14° to 131° F)
Applications
- Dosing Filling, Mixing Applications
Approvals & Certifications
Duty Cycle
- 100% Duty Cycle - Continious Rating
Electrical Connectors
- Cable Plug Typical 2506: Tag Connector Sidewards According to DIN EN 175301-803 (Previous DIN 43650) Form C
Electrical Contacts
- Normally Closed
- Normally Open
Environmental Protection
- IP20 with Tag Connector
- IP65 with Cable Plug
Materials of Construction
Media
- Compressed Air
- Neutral Gases
- Technical Vacuum
Mounting Position
- Preferably with Actuator Upwards
Orifice Size
- 0.03" to 0.04" (0.9 to 1.2 mm)
Pressure Range
- Vacuum - psi: -116 to -145 (kPa: -800 to -1,000, bar: -8 to -10)
Process Temperature
- -10° to 55° C (14° to 131° F)
Response Time
- Opening, Closing: 25 Millisconds Approximately (Pressure Rise 0 to 10%, 100% to 10%)