Model IXLdp Ultra-Low Differential Pressure Transmitter
Brand: Ashcroft Inc.The Ashcroft Industrial IXLdp was designed for the measurement and control of very low pressure and flow in industrial and process plant environments. The Industrial IXLdp transmitter features a rugged NEMA 4X enclosure, built-in electrical terminal box isolated from the electronics and threaded process connections.
The Ashcroft IXLdp transmitter utilizes a state-of-the-art variable capacitance sensor with a glass-clad silicon chip.
The Si-GlasTM technology combines the high sensitivity of a variable capacitance transducer with the repeatability of a micromachined, single-crystal silicon diaphragm. The Si-Glas sensor is composed of sputtered metals and glass molecularly bonded to silicon.
There are no epoxies or other organics in the sensor to contribute to drift or mechanical degradation over time.
Features- Certified 0.25% and 0.5% accuracy
- 0.1" to 200"-H2O pressure ranges
- Optional FM approval for hazardous locations
- NEMA 4X metal construction
- Six types of output signals available
- 5:1 turndown option
- On-board voltage regulation allows use of lower cost, non-precise, unregulated power supply
- Hazardous environments
Specifications
Brand
Accuracy
- ± 0.25% of Span
- ± 0.5% of Span
Applications
- Building Energy Management
- Comfort Control Systems
- Fan Tracking
- Filter Monitoring
- Fume Hoods Control
- Furnace/Stack Draft
- HVAC Equipment
- Laboratory / Clean Room / Hospital Room Pressurization
- Laminar Flow
- Leak Detection
- Medical Equipment
- Pollution Monitoring Equipment
- Velocity Measurements
Approvals & Certifications
- FM
Burst Pressure
- psi: 50 (kPa: 344.7, bar: 3.44)
Compensated Temperature
- -18° to 71° C (0° to 160° F)
Current
- Supply: 2.6 mA Typical for Voltage Output
Damping Adjustment
- 0 to 30 seconds
Diaphragm Material
- Silicone
Electrical Connectors
- Screw Terminal
Electrical Protection
- Reverse Polarity
Enclosure, Body Material
- 300 Series Stainless Steel
Environmental Protection
- IP66
- NEMA 4X
Humidity
- 0 to 95% Relative Humidity
Media
- Clean, Non-Corrosive Dry Gases
Mounting Position Effect
- 0.1" WC: 0.8% of Span/g
- 0.25" up to 0.5" WC: 0.5% of Span/g
- 1" WC & Higher: 0.1% of Span/g
NACE & NIST
- NIST
NPT Connection
- 1/4" NPT Female
Operating Temperature
- -29° to 85° C (-20° to 185° F)
Output
- ± 2.5 Vdc, 3-Wire
- ± 5 Vdc, 3-Wire
- 0-5 Vdc, 3-Wire
- 1-5 Vdc, 3-Wire
- 1-6 Vdc, 3-Wire
- 4-20 mA, 2-Wire
Power
- 12-36 Vdc
Pressure Range
- Inches WC: 0 to 200
Pressure Type
- Compound Pressure
- Differential
- Gauge
Proof Pressure
- psi: 20 (kPa: 137.9, bar: 1.37)
Response Time
- 250 milliseconds
- Fast Response: 8 milliseconds
Span & Zero Adjustments
- ± 10% of Full Scale
Span & Zero Effect
- For ± 0.25% Accuracy: ± 0.01% of Span / °F
- For ± 0.5% Accuracy: ± 0.02% of Span / °F
Stability
- Maximum
Static Pressure
- Maximum
Static Pressure Effect
- < 0.5% of Span
Storage Temperature
- -40° to 98.8° C (-40° to 210° F)
Turndown
- 5:1
Update Time
- Warm-Up Time: < 1 second
Vibration Effect
- Sweep: < 0.2% of Span/g (10 to 130 Hz)